Common trouble of PET strech blowing machine and solutions as following:
Fault 11: The bottom of the bottle is not full
Reasons:
1. The temperature of bottle bottom is too high
2.The exhaust hole at the bottom of the Bottle Mold is not enough or uneven
3.The stretching rod is not at the bottom.
4.The design of stretching rod head does not conform to the shape of the bottom of the preform
5.Blowing pressure isn't sufficient
6.The flow of blowing valve isn't enough
7.The design of the bottle bottom curve is not well
Solution:
1. Reduce the bottom temperature of the heating zone or use wet cloth to reduce that of the embryonic tube
2. Increase the number of exhaust holes and make them evenly distributed.
3. Adjust stretching rod to the bottom of the bottle
4. Replace the head of stretching rod
5. Increase the blowing pressure
6. Clean the blowing valve by gasoline
7. Add streamline design of the bottle bottom curve
Fault 12:
Reasons:
1.It must be owe to the uneven thickness of the embryonic tube if it is in a particular location relative to the tooth of preform
2. It must be owe to the mold exhausting if it is in a particular location relative to the mold clamping line
3. Heating the embryonic tube unevenly
4. The design of the mold bottom is not well
Solution:
1. Improve the thickness design of the preform
2. Improve the exhaust hole of the mold bottom
3. Improve the heating conditions
4. Improve the bottom design
Fault 13:Bottle Blowing Machine indicates no power supply
Reasons:
1.Socket without electricity
2.Insurance tube broken
3.wire leading drops out
4.Safety emergency stopper is not open
5.The power switch isn’t turned on
6.Indicator broken
7.The miniature circuit breaker of heating furnace control socket isn't closed
Solution:
1.Check whether there is electricity in the socket and whether the leakage switch trips
2.Check whether there is a short circuit, and then replace the insurance tube
3.Connecting the Joints well
4.Open the emergency safety switch
5.Turn on the power switch
6.Replace the indicator
7. Close the circuit breaker
Fault 14:No sealing and stretching movements
Reasons:
1.Clamping stroke doesn't reach the designated position
2.The switch of the clamping stroke broken
3.The wire falls of
4.Delay the stretching time,and the relay is damaged
5.The lifting and stretching electromagnetic valve are damaged
6.The inlet and exhaust throttle valve of the cylinder block or shut up
7.The corresponding electromagnetic valve broken
8.Set the delaying stretching time to “0”
Solution:
1.Moving forward the clamping touch block
2.Replace the switch of clamping stroke
3.Connecting the Joints well
4.Change the time relay
5.Change the electromagnetic valve
6.Check the hole to ensure unblocked
7.Check the corresponding electromagnetic valve
8.The delaying stretching time setting is not less than "0"
Fault 15: the disc does not rotate
Reasons:
1.The fuse is broken, and the disc does not rotate
2.The AC contactor and the thermal relay are damaged
3.The electric motor is short of phase (humming)
Solution:
1.The insurance tube resistance is measured with a multimeter block (R (1) .If it is 0,that is good;if it is ∞,that is broken.
2. The double sides voltage of the Ac contactor coil are measured with a multimeter ACV250.If it is 0,measure the voltage between the upper end of the ac contactor coil and thermal relay(96);.if it is 220V,the thermal relay is broken.
3. Connect barge phase line
The above is the Troubleshooting of PET bottle blowing machine we have listed for you. You can submit the following form to obtain more industry information we provide for you.
You can visit our website or contact us, and we will provide the latest consultation and solutions
Send Inquiry
Most Popular
lastest New
Send Inquiry
Send Inquiry
Ms. Cheryl
Email:
Send Inquiry Tel:+86-576-88807095
Fax:
Mobile Phone:+8613905763982
Email:
Address:Shangnian Industrial Area, Taizhou, Zhejiang
Related Products List
Mobile Site
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.